Preeminent Solutions Engineering

Significantly rusted connections, deformed bolts, cracked welds, and failed metal plate connections pose a significant risk to historic buildings under modern loads. Connection failures can be sudden under increased loading.

checklist

Structural & Moisture Distress Checklist
INDEX SIGN YES N/A NO NOTES
1Severe Cracking, Especially Severe Cracking with Bulging
2Excessive Floor Deformation
3Excessive Ceiling Sagging
4Rusted Connection Bolts, Rivets, & Plates
5Deformed Connection Bolts, Rivets, & Gussets
6Fractured Welds
7Concrete Cracking Directly Under Heavy Bearing Plates & Joist Seats
8Metal Deformation
9Unusual Floor Bouncing Once Roofs, Walls, Windows, or Facades Are Opened,
10Peeling, Bubbling, or Cracking
11Musty Odors
12Texture Changes
13Efflorescence
14Visible Mold